3-15
[EZJ126 board external views]
Connector for power
supply
Two hexagonal spacers
for fixing EZJ125
TP321 “PGND”
Connector for battery
connection
Connector for
EZJ125 board
Connector for
model key
Connector for
Language
key
Not mounted on UX-B
Connector for
EZJ128
Connector for
EZJ130
Not mounted
on UX-B
TP323
“SGND”
TP1427
“Print-in-progress”
TP774
“Encoder-N”
TP787
“Sensor-N”
- Please use the Rescue soft when IJP does not normally stand up after exchanging
substrates.
(
Refer to
“
2.21 Rescue soft
”
for detail
)
Caution
!
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...