4-2
4.1.2 Access to the parts on the front side of the equipment
1 Remove the Inner cover (T).
.
2 Remove the fixing screws(2) (2 pieces) and draw the reservoir unit out to the front
halfway by supporting “a” part (4 places) with both hands.
3 Remove the tubes and cables from the clamp.
4 Pull the reservoir unit out further and put it on the maintenance cover.
Reservoir Unit
Maintenance cover
Remove
Clamp
Tube/Cable
Tube/Cable
Clamp
[CAUTION]
Carefully mount the Reservoir unit back
to its place so that the piping tube of
the recovery filter is not pinched.
After performing the task of pulling the
Reservoir unit, please make sure that the
level sensor is functioning normally Street.
Fixing screw(2)
Pull out Reservoir Unit
Reservoir Unit
Inner cover (B)
a
a
【
CAUTION
】
Please do not remove the
rock pin guard.
When you removed any
chance, please return to the
original.
Rock pin guard
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...