4-20
8 Remove the fixing screws (8 positions) which connects both the upper part and the lower
part of the circulation unit. The pump unit can be removed.
"Caution": Put wiping paper under the pump unit to provide for an ink drip.
9 Clean the portion stained with ink and make sure that the O-rings (4 positions) are
securely mounted in the concaves of the lower-side circulation unit. Then, install the
new pump unit in reverse order of the procedures above.
10 Perform “Ink refill” and adjust the pressure. Make sure that there is no ink leak.
11 Reset the pump time to "0" on the “Parts usage time management” screen.
Fixing screws (8 positions)
Pump Unit
ICU fixing plate
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...