6-5
6.2.3 Deflection Voltage Fault
Deflection Voltage
Fault
Is the EZJ125 board CN6
connector or high-voltage
power supply output
connector disconnected?
Connect the connector.
Disconnect the connector and then
reconnect it.
Does the printer
become ready for
printing?
Yes
No
No
Replace the high-voltage
power supply unit.
Does the printer
become ready for
printing?
Yes
No
Replace the EZJ125 board.
END
Does the printer
become ready for
printing?
Yes
No
Replace the EZJ126 board.
END
Yes
END