4-23
4.8.3
Pump head replacement
1
Perform “Ink drainage” to “Pressure relief”.
2
Turn off the power supply.
3 Perform “4.8.2Drive unit replacement procedure” and remove the drive unit .
4
Remove the fixing screws (2 positions) and remove the pump head.
[Example] The following figure below indicates the case of the circulation pump head
removal.
[Caution] Be careful not to lose the O-ring.
O-ring
Pump head (Circulation pump)
Supply pump
Makeup pump
Circulation pump
Recovery pump
Fixing screws (2 pieces)