4-18
4.8 Pump part replacement
4.8.1
Pump Unit Replacement Procedure
1 Perform “Ink drainage” to “Pressure relief”.
2 Turn off the power supply.
3 Perform “4.1.3 Access to the parts on the rear side of the equipment”, “(1) Access
method from the front” and open the unit door.
[Caution] Be careful not to catch the tubes.
4 Remove the wire harness from the clamps (5 positions).
5 Disengage the connectors of the electrical parts (6 positions) (pressure sensor,
viscometer (3 positions), level sensor and float sensor).
5 positions
1 position
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...