2-26
2.9 Backup
●
Print data and user data are backed up on a USB memory.
●
Backup data can be copied on an IJ printer.
●
You can select the type of data when copying to the IJ printer.
●
The copying method is replacing the content of USB memory as they are (overwrite copy).
Types of copy target data
Types of data
Contents
Print data
▪
Includes the settings of print contents, print format and print
specifications.
▪
Registered print data is the target of backup; print target data is
not applicable for backup.
▪
To back up print target data, register them and back up as
registered print data.
Standard
character
Includes standard character patterns in all character sizes.
User pattern
Includes registered characters in all character sizes.
Unit-specific
data
(maintenance
screen setting
values, etc.)
User environment setup, date/time setup, communication
environment setup, circulation environment settings, system
environment setup, auto phase gain value, fault warning history,
touch panel coordinate information, display environment setup,
excitation setting value, viscosity information, login information,
Operating time, Ink alarm time, cumulative operating time, print
count, various usage time, logging data (viscosity data, ink
automatic replenishment data, circulation control data, fault
warning history, entry trace data)
Difference between copy target data maintenance modes
User maintenance mode
Service personnel
maintenance mode
Types of data
Backup
(IJP
USB memory)
Data copy
(USB memory
IJP
)
Backup
(IJP
USB memory)
Data copy
(USB memory
IJP
)
Print data
O
O
O
O
Standard
character
O
O
O
O
User pattern
O
O
O
O
Unit-specific data
O (*1)
X
O (*2)
O (*3)
(*1) Logging data output to binary file only.
(*2) Logging data output to either binary file or text file.
(Refer the chapter 2.20 for Detail of Logging text)
(*3) Can copy when the copy target folder has the same serial number as itself.
Data of multiple IJ printers can be backed up in a single USB memory.
A folder with the product serial number is created in the USB memory.
When copying backup data from the USB memory to the IJ printer, select the folder of the
data is to be copied.
A single USB memory can hold data for up to 100 IJ printers data. However cannot exceed
the capacity of the USB memory.
Use the auxiliary function menu for inserting/removing the USB memory.
Do not frequently insert/remove the USB memory.
When copying standard character pattern, execute the data copy function with the printer in
“Stop” state.
[Note]
Do not use the backup data made by RX model software version before V8.06 to the UX model
with SOP-15-19.
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...