4-27
4.8.5
Gear replacement
1
Turn off the power supply.
2
Referring to 4.8.2 Drive unit replacement procedure and remove the drive unit.
[Caution]
When the drive unit is removed, the springs on the pump head (4 pieces) are freed
causing the internal parts (diaphragms) elongated.
To avoid this, put the drive unit back to its place approximately within 30 minutes.
3
Remove the fixing screws (2 positions) and take out the pump cover.
4
Referring to 4.8.4 Motor replacement, remove the motor.
5
Hold the D-cut of the drive shaft by spanner and remove the hex. head bolt near the gear.
6
Shift the drive shaft as shown by an arrow and remove the shaft from the bearing.
Fixing screws
Pump cover
Motor
Spanner
Hex. head
bolt
Pull out
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...