6-48
6.4.10 Ambient Temperature Too High / Too Low
Ambient temperature
Too High / Too Low
Does the IJ printer
temperature indication agree
with the ambient
temperature?
Is the EZJ125 board CN7
connector disconnected?
Connect the connector.
Yes
No
Yes
No
Replace the EZJ125 board.
Is the
Ambient
temperature
upper-/lower-limit value
erroneously set?
Properly set the
Ambient
temperature upper-/lower-limit
value.
Use an air-conditioner or the like
to ensure that the IJ printer
ambient temperature is within
the operating temperature range.
No
Yes
Is the problem
fixed?
No
Yes
Replace the print head.
END
Is the problem
fixed?
No
Yes
Replace the Thermistor of head cable.
Is the problem
fixed?
No
Yes
Replace the EZJ126 board.
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...