4-56
4.18 Check on Exhaust Duct dripping
The exhaust contains the vapor of makeup and it will be liquefied when cooled down.
Depending on the IJP’s installation environment, there will be a case that there is a big
difference between IJP’s inside temperature and the operating temperature.
When IJP is installed or when IJP is serviced at periodical maintenance, please check the
items below:
(1) Is there any wiring routed around the exhaust duct, such as the power cord, the electrical
signal wirings, etc.? Should there be dripping the wire/cable coating may get cracked.
Please reroute the wiring and call customer’s attention.
(2) Is there any track of the dripping?
Please propose a tray for dripping to customer.
There may be a possibility that the ink/makeup was supplied to the ink/makeup
reservoir more than needed and it overflowed from the reservoir’s vent and ran to the
exhaust duct. Please call customer’s attention.
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...