3-46
3.3.16 DC fan
[Function]
- Input voltage: DC 24V
For air agitation to uniform the controller part air temperature
[Note at the replacement]
- When replacing the DC fan, be sure to turn off the power.
- Be sure to joint the connector.
- When installing the DC fan, pay attention to the mounting direction of NP (name plate)
and harness.
[Replacement procedure of DC fan]
(1) Turn off the main power and open the maintenance door.
(2) Remove the DC fan connector (CN21) on EZJ126 board.
Remove the two fixing screws of fan plate.
(3) Remove the two fixing screws of DC fan , then remove the DC fan.
(4) Install a new DC fan by reversing the above procedure.
Red wire: 24V
Black wire: GND
White wire: Sensor output
Fan plate
Two fixing screws of DC fan
Mark
Two fixing screws of Fan plate
Fan guard
DC fan
Fan guard
Fan guard
Fan plate
DC fan
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...