3-45
3.3.15 High Voltage Power Supply
[Function]
- Deflection voltage output
: DC 5.7kV Max.
Charge signal source voltage output : DC500V
[Note at the replacement]
- When replacing the high voltage power supply, be sure to turn off the power.
- If the high voltage line is dusty, a fault may occur due to a leakage of high voltage.
Wipe the dust off the line in the case where it is dusty.
- When connecting the deflection voltage output connector, be sure to joint the connector
to right position.
[Replacement procedure of high voltage power supply]
(1) Turn off the main power and open the maintenance door.
(2) Remove the wire harness from the wire clamp put on the high voltage power supply
protective cover.
(3) Remove the protective cover of high voltage power supply.
(4) Remove the high voltage power supply.
Remove the two fixing screws and two fixing spacers.
(5) Install a new high voltage power supply by reversing the above procedure.
Check the clamping position of wire harness.
Caution against an electric shock
The high voltage power supply has a portion where high voltage is applied. In order to
avoid an electric shock, be sure to turn off the power before access the high voltage power
supply.
Deflection voltage output
(DC5.7kV MAX)
Charge signal source
voltage output
(DC500V)
Control signal input
For CN6 of EZJ125
Two fixing
screws
Two fixing spacers
Two fixing
screws
Two fixing spacers
High voltage line
With respect to the
clamping position of wire
harness, refer to “3.3.18
Electrical connection
diagram”.
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...