3-25
[Procedure to add the option for UX-B (change to EZJ127A board)]
(1) Turn off the power and be sure not to supply the electric power to the wires connecting
to TB1.
(2) Remove the connectors and change to EZJ127A board. (Two fixing screws)
(3) Insert the connectors and perform the setting of SW1 and 2.
(4) Turn on the power.
(5) Input a special password for service maintenance mode on the select login user menu.
(6) Press “Option setup” button at the second page of the maintenance menu.
(7) Change the software option 20 “Standard communication B” to “Enable”.
(8) Return to the user maintenance mode on the password protection menu.
With respect to the setting
of service maintenance
mode, refer to “2.1 Setting
of maintenance mode by
service personnel”.
Option setup
button
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...