2-25
2.8 System reset
●S
et the set values on the “Printing data”, “User pattern” and “Maintenance” screens to the values of
initial condition.
●
Perform this function when the EZJ128 board or the EZJ126 board is replaced in a state allowing
no backup.
●
If this function is performed, perform setup and/or adjustment according to the contents described
in “3.2.4 EZJ128 board.” and “3.3.1 EZJ126 board.”
●
This setting is carried out with the IJ printer in “Stop” state.
1 The maintenance menu is displayed.
If Prev. menu Next menu is not displayed on the maintenance menu, set the service
personnel maintenance mode on the login user selection screen.
2 Press System reset on the second page of the maintenance menu.
The confirmation message is then displayed.
3 Press OK .
“Please wait” is displayed.
After the completion of the system reset, the screen returns to the service maintenance
screen.
〔
For work after System reset
〕
Please execute work according to [3.2.1 EZJ128 board (controller board) (12)-(13) of
replacement procedurenotes].
Please execute work according to [3.3.1 EZJ126 board (MPU board) (12)-(13) of
replacement procedure].
For information on changing to the service personnel maintenance mode,
refer to “2.1 Setting of service personnel maintenance mode.”
= = = = = System Reset Confirmation = = = = =
241
OK
Cancel
The system will be reset.
This function is executed upon replacement of Board
EZJ128 or EZJ126.
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...