5-24
5.14
Head Cable Replacement Procedure
1
Refer to
「
4.13 Print head replacement procedure
」
for separatingto console and head cable.
2
Remove the head cover and heater cover.
3
Perform
「
5.12
Head base replacement procedure
」1~5
and
7~9
4
Remove the screws(4 PCS.) as shown below.
5
Pull out the wires and tubes.
6
Attach the new head cable.
(
1
) As re-install the cables and tubes, pay attention totake of Edge guard and breakcables and tubes.
。
(
2
) Refer to
「
4.13 Print head replacement procedure
」12
for connection of console and head cable.
(
3
) Refer to
「
5.12Head base replacement procedure
」1~5
and
7~9
for connecting the Print head
and the Head cable
.
Edge guard
Caution against an electric
There is work of opening the maintenance door. In order to avoid an electric shock, be
sure to turn off the power before access the high voltage power supply.
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...