3-32
[Connection to the external connection terminal block (EZJ119A -TB2) ]
Pin
Name
Remarks
1
Ready
NC
30VAC/0.5A or 30VDC/1A
2
NO
30VAC/0.5A or 30VDC/1A
3
COM
4
Fault
NC
30VAC/0.5A or 30VDC/1A
5
NO
30VAC/0.5A or 30VDC/1A
6
COM
7
Warning
NC
30VAC/0.5A or 30VDC/1A
8
NO
30VAC/0.5A or 30VDC/1A
9
COM
Terminal specification: M4
[Setting of switch 3]
The ready output selector switch (SW3) is used to enable or disable the ready signal
output.
Switch setting
Ready output status
When this setting is employed, the ready output signal is enabled.
The path between the TB2 terminals opens or closes depending
on whether the IJ printer is ready.
When the NC contact (break contact) is used, the ready output
signal is disabled. The path between the TB2 terminals opens as
shown in the table below no matter whether the IJ printer is ready.
When the NO contact (make contact) is used, the ready output
signal is disabled. The path between TB2 terminals 1 and 3 opens
and the path between TB2 terminals 2 and 3 closes as shown in the
table below no matter whether the IJ printer is ready.
SW3
3
1
2
SW3
3
1
2
SW3
3
1
2
(
Default
)
Ready state
Not-ready state
TB2
1-3 contact
Open
1-3 contact
Closed
2-3 contact
Closed
2-3 contact
Open
Ready state
Not-ready state
TB2
1-3 contact
Open
1-3 contact
Open
Ready state
Not-ready state
TB2
2-3 contact
Closed
2-3 contact
Closed
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...