4-37
4.12 Troubleshooting when Fault Occurs in Viscometer
Follow the troubleshooting steps below when the error occurs in viscometer.
[Caution] If “Viscosity Reading Instability” or “Viscosity Readings Out of Range” is
occurred , the IJP will automatically switch to the dot count system and operate.
(1) Viscosity Reading Instability
・
Phenomenon: Some unevenness occurred in 5-times measurement results of fall
time. (The difference between the maximum and minimum values
of fall time exceeded 10% of average value.)
・
Estimated cause: Entrance of foreign object
Troubleshooting:(a)
Retry “calibration”. If the fault is not recovered, proceed to (b).
(b) Disassemble and clean viscometer. Proceed to (c) if no
recovery is made.
(c) Replace viscometer.
(2) Viscosity Readings Out of Range
・
Estimated cause: Ink adhered to the IN-side of viscometer.
Troubleshooting: Disassemble and wash viscometer.
・
Estimated cause: Proximity sensor was faulty.
Troubleshooting: Replace the proximity sensor.
If there is no recovery with the above troubleshooting, replace the viscometer.
(3) Inside Temperature Too High
・
Cause: Thermistor was faulty.
Troubleshooting: Confirm the connection of connector and/or replace the thermistor.
4.12.1 Viscometer removal procedure
[Caution] Disposing of ink is not necessary.
1 Removing the viscometer IN-side tube
(A) Follow the procedures described in “4.1.2 Access to the parts on the front side of
the equipment” and make the viscometer visible.
(B) Release the viscometer IN-side tube (mark G) from the clamp.
(C) Turn the lock nut to remove it.
Fixing screws
Viscometer
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...