4-16
4.7 Circulation Unit Replacement Procedure
1 Perform “Ink drainage” and then “Pressure relief”.
2 Turn off the power supply.
3 Perform “4.1.2 Access to the parts on the front side of the equipment” and draw out the
reservoir unit.
4 Perform “4.1.3 Access to the parts on the rear side of the equipment” “(1) Access method
from the front” and open the unit door.
[Caution] Be careful not to catch the tubes.
5 Remove the tubes (13 positions*) that are connected to the circulation unit.
*14 positions for UX-E.
[Caution] Be careful about ink dripping.
[Caution]
On Model UX-E, when you replace circulation unit which was mounted in
the printer with replacement part, replace the plug on the replacement part with the ICU
joint which is delivered together .
6 Remove the wire harness from the clamps (5 positions).
*:UX-E
only
Tubes (13 positions*)
14 positions for UX-E.
Summary of Contents for IJ UX
Page 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Page 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Page 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Page 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Page 107: ...3 27 Circuit diagram of EZJ127A ...
Page 108: ...3 28 Circuit diagram of EZJ127B ...
Page 122: ...3 42 Circuit diagram of EZJ129 ...
Page 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Page 132: ...3 52 ...
Page 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Page 302: ...Circulation System Diagram UX E 7 2 ...
Page 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Page 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...