6-42
6.4.10 Ambient Temperature Too High / Too Low
Ambient temperature
Too High / Too Low
Does the IJ printer
temperature indication agree
with the ambient
temperature?
Is the EZJ125 board CN7
connector disconnected?
Connect the connector.
Yes
No
Yes
No
Replace the EZJ125 board.
Is the
Ambient
temperature
upper-/lower-limit value
erroneously set?
Properly set the
Ambient
temperature upper-/lower-limit
value.
Use an air-conditioner or the like
to ensure that the IJ printer
ambient temperature is within
the operating temperature range.
No
Yes
Is the problem
fixed?
No
Yes
Replace the print head.
END
Is the problem
fixed?
No
Yes
Replace the EZJ126 board.