REV0 10.02.15
-H8-14-
8.3.5 Replacing the Scanner ASSY
Eject Guide
Bind-heads screw
Bind-head screw
Bind-head screw
Bind-heads screw
①
Remove the Main Cover (L), (R) Side Cover
(R). For instructions, please refer to “8.1
Preparation”
②
Unscrew 4 screws on the Eject Guide and
remove the Eject Guide
③
Remove the Imprinting ASSY. For instructions,
please refer to “8.3.9 Replacing the Imprinting
ASSY (Imprinting Head)”
④
Unscrew 4 bind-head screws on the Plate
(DRV2)
#64 LAMP INVERTER
Bind-he ads screw
Bind-head screw
#26 SS P/K ASSY(CPS618 P/K)
Plate(DRV2 )
⑤
Disconnect 2 connectors (J71, J72) attached to
the Lamp Inverter
⑥
Disconnect 2 connectors (J101, J102) attached
to SS P/K ASSY (CPS618 P/K)
⑦
Disconnect cable from the Clamp
⑧
When removing the Plate (DRV 2), push the
cable to the side so it does not get damaged.
⑨
Remove Cover Sheet
assembly. For
instructions, please refer to “8.3.14 Replacing
the Cover Sheet assembly”
⑩
Remove Lamp ASSY (Front). For instructions,
please refer to “8.2.3 Replacing the Fluorescent
Lamp”
Tools Needed: Magnetic Philips Screwdriver (No.2)
make sure to connect it straight into the device
When connecting the mirror motor connector, make sure
to connect it straight into the device.
CAUTION
CAUTION
CAUTION
CAUTION
Disconnect
it straight
Summary of Contents for HT-4139-28
Page 1: ...HT 4139 28 48 Scanner Maintenance Manual ...
Page 2: ......
Page 11: ... H2 5 2 5 Block Diagram ...
Page 22: ...REV0 10 02 15 H3 10 Lens Mirror Motor Mirror No 1 Mirror No 3 Mirror No 2 ...
Page 35: ...REV0 10 02 15 H7 2 ...
Page 63: ...REV0 2010 02 15 H7 30 ...
Page 89: ...REV0 10 02 15 H8 26 ...