![Hitachi HT-4139-28 Maintenance Manual Download Page 50](http://html.mh-extra.com/html/hitachi/ht-4139-28/ht-4139-28_maintenance-manual_145876050.webp)
REV0 2010.02.15
-H7-17-
(4) Confirm displayed results.
Results of the Automatic judgment is shown like
the display at the left.
If results shows “NG”, clean the scanning Assy,
paper feeding pate and resume scanning.
If it is not fixed, check the contents in the box
below.
If anything wrong is found replace the device.
(5) Click the “Confirmed” button.
(6) As it returns to the dialog (1), change parameters
and resume scanning.
Normally perform Pencil – Red – Surface (back)
(7) Click the “Finish” button to finish
Fig.3
Position of recognition
In case of “NG”
Check if (1)-(4) are normal because the results varies depend on,
(1) Print quality, (2) Sheet contamination, (3) Accuracy of the block, (4) Accuracy of the skew, etc.
(Reading position of marks are shown in the Fig.3)
If nothing is wrong replace the device because it might be abnormal condition of device.
< Judgment > Automatic judgment
The value of the “T
OTAL AVR” should be in the
criteria.
(The AVR value will be displayed in 10 time value
as shown in the example.
(Example: 8.30→83)
Display OK or NG
Summary of Contents for HT-4139-28
Page 1: ...HT 4139 28 48 Scanner Maintenance Manual ...
Page 2: ......
Page 11: ... H2 5 2 5 Block Diagram ...
Page 22: ...REV0 10 02 15 H3 10 Lens Mirror Motor Mirror No 1 Mirror No 3 Mirror No 2 ...
Page 35: ...REV0 10 02 15 H7 2 ...
Page 63: ...REV0 2010 02 15 H7 30 ...
Page 89: ...REV0 10 02 15 H8 26 ...