REV0 2010.02.15
-H7-23-
7.8.5.3 Ultra sonic sensor level
(1)
Confirm the best gain of the Ultra sonic sensor.
Refer to “7.8.4.4 Ultra Sonic Sensor”
(2) “Level of ultrasonic sensor” in the “Information
display of Photo / Video level / SW/ Supersonic
sensor” dialog, specify parameters and click the
“RUN” button.
・
Gain of ultrasonic sensor: xx
(
Specify the gain
confirmed at (1)
)
・
Motor: Main(default)
・
Motor speed: 0.822 m/s(default)
・
Sensor sending wave: Exists (default)
・
Motor operation: Detected
(
default
)
・
Lamp mode 1: Light on (default)
・
Lamp mode 2: Light off
If necessary, change parameter and perform this.
(3)Level of ultrasonic sensor will be displayed every a
few second
To fix the screen, click the “Pause” button.
The “Pause” button will be changed to the “FINISH”
button. To finish display, click the “FINISH” button.
NOTE: The ultra sonic sensor detects dual paper feed by checking its level reduced by air layer between
papers.
The level of the ultra sonic sensor is mostly constant.
Check if it works correctly by changing the number of sheets on the feeding mechanism
The figure below shows an example of level change during paper feeding.
(
AF
)
(
19
)
Single sheet
Single sheet
Dual sheet
FF
0
threshold
37
no sheet
threshold < Level
Judgment 0
None or 1
threshold > Level
judgment1
more than 2
EC
Value for more than one
Value for more than two
Summary of Contents for HT-4139-28
Page 1: ...HT 4139 28 48 Scanner Maintenance Manual ...
Page 2: ......
Page 11: ... H2 5 2 5 Block Diagram ...
Page 22: ...REV0 10 02 15 H3 10 Lens Mirror Motor Mirror No 1 Mirror No 3 Mirror No 2 ...
Page 35: ...REV0 10 02 15 H7 2 ...
Page 63: ...REV0 2010 02 15 H7 30 ...
Page 89: ...REV0 10 02 15 H8 26 ...