REV0 2010.02.15
-H7-22-
7.8.5.2 VIDEO Level
(1)Specify parameters and click the “RUN” button.
・
Video gain
:
All gain
(
default
)
・
Lamp mode1
:
Light on
(
default
)
・
Lamp mode2
:
Light off
(
default
)
・
Skeet face for measurement
:
Surface
(
default
)
・
Sensing direction(Y)
:
White
(
default
)
・
Specified step
:
0
(
default
)
・
Detection area 1 ~ 7500
(
default
)
If necessary, change parameter and perform this.
(2)Level of video will be displayed every a few second
To fix the screen, click the “Pause” button.
To finish display, click the “FINISH” button.
Sample1
Specified step: 0 / Sensing direction(Y): White
Sample2
Specified step: 4 / Sensing direction(Y): White
NOTE:
・
Values of the ODD
、
EVN are approximation at each gain.
・
at the Video gain “All gain”, the level will not change or if variation is large check the lamp condition.
・
If specified step is “0”, displayed level maybe about “0020”.
(
No output because it locates at the
reading position mirror
)
・
In case of the specified step 4, white with Y position, displayed level maybe as shown above “03FF
~
0000” and is getting reducing.
(
The gain is large at 03FF and display large value.
)
・
As a cause of problem, consider failure of the lower mirror (surface), the cover sheet (surface9, the
lower mirror (back), the cover glass (back), CPS615 P/K, the scanner ASSY, MAIN_P/K_ASSY.
As the position of white peak detection is reference, value out of specifications may be displayed.
Summary of Contents for HT-4139-28
Page 1: ...HT 4139 28 48 Scanner Maintenance Manual ...
Page 2: ......
Page 11: ... H2 5 2 5 Block Diagram ...
Page 22: ...REV0 10 02 15 H3 10 Lens Mirror Motor Mirror No 1 Mirror No 3 Mirror No 2 ...
Page 35: ...REV0 10 02 15 H7 2 ...
Page 63: ...REV0 2010 02 15 H7 30 ...
Page 89: ...REV0 10 02 15 H8 26 ...