REV0 2010.02.15
-H7-24-
7.8.6 Mechanical operation
7.8.6.1 Motor operation
(1)Specify parameters and click the “RUN” button.
The specified motor starts rotating with specified
mode.
To finish the mechanical operation, click the “FINISH”
button.
#1 Category: Main*/T1/Eject/Pick/
Main+T1+Eject/All
#2 Motor Speed: 0.822*/0.547/0.411/0.273 m/s
#3 Operation Mode: Continuation*/
interval A/interval B
(2)If you want to stop operation, click the “Pause”
button.
(3)Click the “OK” button.
NOTE* Confirm the specified motor is working without any abnormal noise.
Parameter
Operation
Stop condition
Continuous
Continuous rotation mode
10 minutes
interval A
Repeat 1 second rotation and 0.004 second stop
500 rotations
interval B
Repeat 1 second rotation and 1 second stop
500 rotations
Summary of Contents for HT-4139-28
Page 1: ...HT 4139 28 48 Scanner Maintenance Manual ...
Page 2: ......
Page 11: ... H2 5 2 5 Block Diagram ...
Page 22: ...REV0 10 02 15 H3 10 Lens Mirror Motor Mirror No 1 Mirror No 3 Mirror No 2 ...
Page 35: ...REV0 10 02 15 H7 2 ...
Page 63: ...REV0 2010 02 15 H7 30 ...