63
_____________________________________________________________________________________________
9.4 Control
______________________________________________________________________________________________
9.4.2 Starting/Aborting Measurement
9.4.3 Receiving Waveform Data
Loggers will send the following events:
Measurement start
Sent when measurement is started.
Trigger notification
Sent when a trigger is activated.
Measurement end
Sent when the set recording time of measurement has been reached.
Text saving end
Sent when text data has been saved to a PC card.
Measurement abort
Sent when measurement is interrupted.
Real-time measurement start
Sent when real-time measurement is started via the 9334 LOGGER
COMMUNICATOR. When this event is received, the 9334 stops monitoring
the logger.
Alarm
Sent when an alarm occurs. (8420-01, 8421-01 Ver2.00 or later)
Notification mode start
Sent when monitoring by the logger-monitoring program is started by
operation on the logger.
Notification mode end
Sent when monitoring by the logger-monitoring program is ended by
operation on the logger.
Listener change
Sent when another logger-monitoring program starts monitoring. When this
event is received, the 9334 stops monitoring the logger.
Selecting the monitored logger on the list and clicking [
End Monitor
] ends
monitoring.
You can start or abort measurement of the logger being monitored.
Select the logger you want to control from the list, then click the <
Storage
>
or <
Abort
> button.
You can receive waveform data saved in the storage memory of the logger
being monitored.
Select the logger you want to receive the waveform data from the list, then
click the <
Receive
> button. The "
Receive Waveform Data
" dialog box will
then appear provided that [
Set at every reception
] is selected on "
Properties
"
for the logger. Type in the location where to save the data and the filename.
Then click the <
Receive
> button.
After the data has been received, the path of the file will appear on the log.
Move the mouse pointer to the line where the file path is displayed, and
double-click it to open the file on the 9334 LOGGER COMMUNICATOR.
You can also right-click the line to open a pop-up menu. Choose [
Open
] or
[
Explorer
] to open the file or to browse using Explorer.