Access Controller
·
User Manual
13
No.
DS-K2604-G
C24
COM4
D1
Event Input
C8
Event Alarm Input 8
D2
GND
Grounding
D3
C7
Event Alarm Input 7
D4
C6
Event Alarm Input 6
D5
GND
Grounding
D6
C5
Event Alarm Input 5
D7
C4
Event Alarm Input 4
D8
GND
Grounding
D9
C3
Event Alarm Input3
D10
C2
Event Alarm Input 2
D11
GND
Grounding
D12
C1
Event Alarm Input 1
Notes:
The Alarm input hardware interface is normally open by default. So only the normally open
signal is allowed. It can be linked to the buzzer of the card reader and access controller, and
the alarm relay output and open door relay output.
Arming region alarm input is only for the alarm relay output linkage.
RS485 card ID should be set as 1to 8. For example, the ID of door 1 is 1 and 2 standing for in
and out respectively.
For single-door access controller, the Wiegand card reader 1 and 2 respectively correspond to
the entering and exiting card readers of door 1. For two-door access controller, the Wiegand
card reader 1 and 2 respectively correspond to the entering and exiting card readers of door 1 ,
and the Wiegand card reader 3 and 4 respectively correspond to the entering and exiting card
readers of door 2. For single-door access controller, the Wiegand card reader 1, 2, 3 and 4
respectively correspond to the entering card readers of door 1, 2, 3, and 4.