Access Controller
·
User Manual
97
2.
Select a custom wiegand on the left of the interface.
3.
Check
Enable
checkbox to enable the custom wiegand.
4.
Set the wiegand name.
5.
Select device.
1)
Click
Select Device
.
2)
Select the device need to use custom wiegand.
3)
Click
OK
to save the settings.
6.
Input the Total Length and select the parity mode in the drop-down list.
If you select Odd-Even Parity, you should set the odd parity start bit, the odd parity length, the
even parity start bit and the even parity length.
If you select XOR Parity, you should set the XOR parity start bit, length per group and total
length.
If you select None, you are no need to set the parity mode.
7.
Set output transformation rule.
1)
Click
Set
Rule
to pop up the Set Output Transformation Rules window
.
2)
Select rules on the left list.
Note:
Press the
Shift
key to select multiple rules.
3)
Click
to move the selected rules to the right list.