Access Controller
·
User Manual
101
Alarm Triggered
Pop-up Image
The image with alarm information pops up when alarm is
triggered.
7.10.2
Access Control Alarm Input Linkage
Purpose:
The access control alarm inputs can be linked to some actions (e.g., alarm output, host buzzer)
when it is triggered.
Note:
The linkage here refers to the linkage of the client software’s own actions.
Steps:
1.
Click
Access Control Alarm Input
tab to enter the following interface.
2.
In the event list on the left, select an alarm input.
3.
Switch the property from
to
to enable this action.
Host Buzzer
: The audible warning of controller will be triggered.
Card Reader Buzzer
: The audible warning of card reader will be triggered.
Alarm Output
: The alarm output will be triggered for notification.
Access Control Point (Open/Close)
: The door will be open or closed when the case is triggered.
Note:
The Door cannot be configured as open or closed at the same time.
4.
Click
Save
button to save the settings.
7.10.3
Event Card Linkage
Click
Event Card Linkage
tab to enter the following interface.
Notes:
The Event Card Linkage should be supported by the device.