92
A . N .
B a t t e r y M o d e l S t a t u s
ID-Name
Message ID
Data Length
Sender
Receiver
Cycle Time
CH_BAT_MODEL_QUERY
0x351 => Channel 1
0x352 => Channel 2
0 Byte
Remote
DSP
CH_BAT_MODEL_STATUS
0x141 => Channel 1
0x142 => Channel 2
8 Byte
DSP
Remote
-
Byte
Bits
Values
Name
Resolution
Description
0-1
0-15
0..65355
R1_SET
0,1 m
Ω
Set value of R1
2-3
16-31
0..65355
R2_SET
0,1 m
Ω
Set value of R2
4-5
32-47
0..65355
C_SET
0,1 F
Set value of C
6
48-55
0..255
BAT_MODELL
1
Battery model
A . O .
D e v i c e E r r o r M e s s a g e s
On this message the internal error memory is read out and the error counter is reduced by 1. There are two types of answer
that use a different time stamp. Original time stamp references the time since the start of the SW. New time stamp references
the time since 1970-01-01 in ms
ID-Name
Message ID
Data Length
Sender
Receiver
DEV_QUERY_READ_ERROR 0x360
1 Byte
Remote
ERS
Byte
Bits
Name
Description
0
0-7
SELECTION
0 = answer 1, timestamp in ms since last SW restart
1 = answer 2, timestamp in ms since 1970-01-01
Information:
Only one type may be used. The internal error counter will be reduced by one for each message sent.
ID-Name
Message ID
Data Length
Sender
Receiver
DEV_READ_ERROR_ACK
0x1E0
8 Byte
DSP
Remote
Byte
Bits
Values
Name
Description
0
0-7
0..65355
DEV_ERR_NO
Error memory number
1
8-15
2
16-23
0..65355
DEV_ERR_CODE
Device error code
3
24-31
4-7
32-63 0..FFFFFFFFh TIMESTAMP
Timestamp in ms
ID-Name
Message ID
Data Length
Sender
Receiver
DEV_READ_ERROR_NEW_ACK
0x1C0
8 Byte
DSP
Remote
Byte
Bits
Values
Name
Description
0
0-5
0..63
DEV_ERR_NO
Error memory number
0
6-7
0..65355
DEV_ERR_CODE
Device error code
1
8-15
2
16-21
2-3
22-31
0..1023
TIMESTAMP 0
Timestamp in ms
4-7
32-63
0..FFFFFFFFh
TIMESTAMP 1
Timestamp in s since 1970-01-01