6.4 Device Operating Menus
58
Channel-Parameter
Main Menu=> Setup-Menu => Channel-Parameter DC-Output[x]:
In this menu you can set the parameters of the output channels.
Table 31 Menu Channel Parameter
Designation
function
Function
Select the function of the channel (Battery test or
simulation), if the option is available
Sense-Monitoring
If the limit for the voltage difference between output
voltage and sense input is exceeded, the device is
switched off after the set delay and an error
message is displayed
Int. Voltage monitoring
Switch-off threshold and delay time for internal volt-
age monitoring
Output voltage monitoring
Switch-off threshold and delay time for monitoring
the output current
Output current monitoring
Switch-off threshold and delay time for monitoring
the output current
Averaging
Number of interpolation points for forming the mean
values for displaying the actual values in the display.
The measured values transmitted via the CAN
interface are not filtered.
Type of set value ramp
Type of set value ramp (constant speed/ constant
time)
Rapid Discharge (optional)
Activate/deactivate rapid discharge of the test
sample (only for Batt.-Sim.)
Fig. 51 Menu – Channel-Parameter