8.6 Error Messages
74
Table 39 Error messages
Code
Name
Description
0x11
COM_DSP1_ERR
SPI timeout DSP1
0x12
COM_DSP2_ERR
SPI timeout DSP2
0x13
COM_ADC1_ERR
SPI Error ADC channel 1
0x14
COM_ADC2_ERR
SPI Error ADC channel 2
0x15
COM_ADC3_ERR
SPI Error ADC channel 3
0x16
C_MON_0_ERR
Zero value of ADC output current
0x17
C_MON_POS_ERR
Pos. output current limit reached
0x18
C_MON_NEG_ERR
Neg. output current limit reached
0x19
C_MON_HTS1_0_ERR
Zero value of ADC inductor current
0x1A
C_MON_HTS1_POS_ ERR
Pos. inductor current limit reached
0x1B
C_MON_HTS1_NEG_ERR
Neg. inductor current limit reached
0x1C
V_MON_SEC_0_ERR
Zero value of ADC secondary voltage
0x1D
V_MON_SEC_OV_ERR
Overvoltage limit reached secondary voltage
0x1E
V_MON_SEC_UV_ERR
Undervoltage limit reached secondary voltage
0x1F
TEMP_CB_ERR
Over temperature Control Unit
0x20
AFE_CHOP_ERR
AFE Chopper timeout
0x21
OVP_SENS_ERR
Overvoltage protection triggered
0x22
OCP_ERR
Overcurrent protection triggered
0x23
OVP_SEC_ERR
AFE Chopper timeout
0x24
OVP_PRI_ERR
Overvoltage protection triggered
0x25
CAN_IO_ERR
CAN module error
0x26
SENSE_ERR
Difference between sense and internal voltage to high
0x27
EEPR_CHKSUM_ERR
EEPROM Checksum error
0x28
E_STOP_ERR
SW-E-Stop
0x29
REMOTE_TIME_ERR
Remote control interface timeout
0x2A
DSP2_ERR
Error during data transfer DSP2/FPGA
0x2B
CH_STOP_ERR
Channel was switched on during active channel stop
0x2C
60V_SWITCH
FPGA status monitoring of the other channel/unit
0x2D
DEV_ART_NO
Cluster mode, ERS units not identical
0x2E
FLOW_CTRL_UT_ERR
Error message from flow monitor undertemperature