Manual ERS-BIC 160 kW V2.1
91
0-1
0-15
0..65355
V_MON_SENS_A
0.1V
Averaged voltage measured at the sense
2-3
16-31
-32768…
32767
C_MON_A
0.1A
Averaged Amperage measured at the output
4-5
32-47
-32768…
32767
P_MON_A
<325kW
10W
>325kW
100W
Averaged Wattage measured at the sense
A . K .
M a x i m u m S e t V a l u e s
ID-Name
Message ID
Data Length
Sender
Receiver
Cycle Time
CH_MAX_SET_VAL_QUERY
0x331 => Channel 1
0x332 => Channel 2
0 Byte
Remote
DSP
-
CH_MAX_SET_VAL
0x131 => Channel 1
0x132 => Channel 2
8 Byte
DSP
Remote
Variable 1
Byte Bits
Values
Name
Resolution
Description
0-1
0-15
0..65355
V_SET_MAX
0,1 V
maximum set value voltage
2-3
16-31
-
32768 …3276
7
C_SET_MAX
0,1 A
maximum set value current
4-5
32-47
-
32768 …3276
7
P_SET_MAX
<325 kW
10 W
>325 kW
100 W
maximum set value power
A . L .
C H A R G E / D I S C H A R G E R e g i s t r y
ID-Name
Message ID
Data Length
Sender
Receiver
Cycle Time
CHARGE_DISCH_QUERY
0x341 => Channel 1
0x342 => Channel 2
0 Byte
Remote
DSP
CHARGE_DISCHARGE
0x161 => Channel 1
0x162 => Channel 2
8 Byte
DSP
Remote
Byte
Bits
Values
Name
Resolution
Description
0-3
0-31
0.. FFFFFFFFh CHARGE_LOW
0,1 As
4-7
32-63 0.. FFFFFFFFh DISCHARGE_LOW
0,1 As
A . M .
B a t t e r y M o d e l
ID-Name
Message ID
Data length Sender
Receiver
Cycle Time
CH_BAT_MODEL
0x211 => Channel 1
0x212 => Channel 2
8 Byte
Remote
DSP
-
Byte
Bits
Values
Name
Resolution
Max./Min
Description
0-1
0-15
0..65355
R1_SET
0,1 m
Ω
0…10000
Set value for R1
2-3
16-31
0..65355
R2_SET
0,1 m
Ω
0…10000
Set value for R2
4-5
32-47
0..65355
C_SET
0,1 F
0…1000
Set value for C
6
48-55
0..255
BAT_MODELL
1
0…4
Selection of battery model