88
A . E .
C h a n n e l C o n t r o l
ID-Name
Message ID
Data Length
Sender
Receiver
Cycle Time
CH_CTRL
0x201 => Channel 1
0x202 => Channel 2
8 Byte
Remote
DSP
Timeout monitoring
Byte Bits Values
Name
Description
0
0
0..1
ON
Activate channel
1
0..1
HV_ON
Close output contactors
2
0..1
Q_CH_ERROR
Acknowledgement of channel errors.
Clears all channel errors in the register, not the error memory
3
0..1
Q_CH_WARNING
Acknowledgement of channel warnings.
Clears all channel warnings in the register, not the warning memory
4
0..1
CH_STOP
Channel stop
5-7
0..4
CTRL_MODE
1: CV-Mode => voltage controlled
2: CC-Mode => current controlled
4: CP-Mode => power controlled
1
8-11
0..8
PAR_ID
Choose parameter-set
12
0..1
RESET_Q
Reset Coulomb-Counter
14-15 0..2
OPER_MODE
Battery test mode:
0: PAUSE
1: DISCHARGE
2: CHARGE
Battery simulation:
0: BIDI
1: SINK
2: SOURCE
2-3
16-31 0..65355 V_SET
Voltage set value /0.1 V
4-5
32-47 0..65355 C_SET
Amperage set value /0.1 A
6-7
48-63 0..65355 P_SET
Wattage set value /10 W
A . F .
C h a n n e l C o n t r o l I I
ID-Name
Message ID
Data Length
Sender
Receiver
CH_CTRL_II
CH1: 0x251
CH2: 0x252
8 Byte
Remote
DSP
byte
bits
values
name
description
0
0
0..1
BATT_MODE
0: Battery Test Mode on
1: Battery Simulation Mode on
1
HV--_ON
2
SHORTCUT
1
8
0..1
RAMP_MODE_CTRL_V
Control the ramp of voltage control
speed = 0 /
time = 1
9
0..1
RAMP_MODE_CTRL_C
Control the ramp of current control
speed = 0 /
time = 1
10
0..1
RAMP_MODE_CTRL_P
Control the ramp of power control
speed = 0 /
time = 1