Manual ERS-BIC 160 kW V2.1
11
Table 8 Cooling
Coolant
Water
Material heat sinks
Aluminum
Supply temperature
18°C … 24°C
Operating pressure
2.5 … 5 bar
Pressure loss
ca. 1.5 bar (higher at glycol content >10%)
Required flow rate
28 l/min
Cooling power
12 kW
Connection
Ø
1“
Requirements on Coolant
See
Table 16, p. 23
Positioning of coolant
connection
See
section 5.3.3, p. 23
Table 9 Battery Models
Range internal resistance
0.1 – 1
Ω
[resolution 0.1
m
Ω]
Battery model (optional)
3 standard battery models as RC network integrated.
Table 10 Environmental Conditions
Operating temperature
+5 … + 40°C
Humidity
15 … 70% (non condensing at 18°C)
Table 11 Standards
Protection class
according EN
60529
IP 22 (with installed base covering)
EMC
EN 61000-6-2 (grade 3)
EN 61000-6-4 (grade 4)
Harmonic Distortion
THDV = 1.7% (typical)
Noise emission
Noise level (A)
≤
64 dB