90
A . H .
C h a n n e l S t a t u s I I
ID-Name
Message ID
Data Length
Sender
Receiver
Cycle Time
CH_STATUS_II_QUERY
0x381 => Channel 1
0x382 => Channel 2
0 Byte
Remote
DSP
-
CH_STATUS_II
0x151 => Channel 1
0x152 => Channel 2
8 Byte
DSP
Remote
Variable 1
Byte
Bits Values
Name
Description
0
0
0..1
REMOTE_HW
Channel control via remote interface is active
(Hardware option)
1
0..1
HV_RELAIS_M
State HV-Minus-Output contactors
2
0..1
SHORTCUT
State short circuit test, On/Off
1
8-9
0..3
OVERLOAD
0: No overload operation
1: Ready => overload operation released and possible
2: Active => overload operation is active
3: Limiting => max. overload limit has been reached, cooling down
A.I .
Curr en t vali d s et va lu e s
The DSP checks the new transferred set values (see message channel control) for validity within the positive or negative
limits. If they are above the limits, the set points are limited to the limits. The valid set values are output periodically, only in
case of changes or only after request at the remote interface.
ID-Name
Message ID
Data Length
Sender
Receiver
Cycle Time
CH_SET_VAL_QUERY
0x311 => Channel 1
0x312=>Channel 2
0 Byte
Remote
DSP
-
CH_SET_VAL
0x111 => Channel 1
0x112=> Channel
2
8 Byte
DSP
Remote
Variable 1
Byte
Bits
Values
Name
Resolution Description
0
0-7
0..65355
V_SET_ACT
0,1V
set value voltage, LSB
1
8-15
set value voltage, MSB
2
16-23
-32768...
32767
C_SET_ACT
0,1A
set value current, LSB
3
24-31
set value current, MSB
4
32-39
-32768…
32767
P_SET_ACT
<325kW
10W
>325kW
100W
set value power, LSB
5
40-47
set value power, MSB
A . J .
C u r r e n t a c t u a l v a l u e s
The actual values are output periodically, only in case of changes or only after request at the remote interface.
ID-Name
Message ID
Data Length
Sender
Receiver
Cycle Time
CH_ACT_VAL_QUERY
0x321 => Channel 1
0x322 => Channel 2
0 Byte
Remote
DSP
-
CH_ACT_VAL
0x121 => Channel 1
0x122 => Channel 2
8 Byte
DSP
Remote
Variable 2
Byte
Bits
Values
Name
Resolution
Description