Chapter 6 List of Parameters GK600E User Manual
- 92 -
Parameter
Designation
Scope
Factory
default
Attr
d1-01
V/f FREQ value f3
0.00Hz~motor rated FREQ
50.00Hz
×
d1-02
V/f voltage value V3
0.0%~100.0%
100.0%
×
d1-03
V/f FREQ value f2
d1-05~d1-01
15.00Hz
×
d1-04
V/f voltage value V2
0.0%~100.0%
35.0%
×
d1-05
V/f FREQ value f1
d1-07~d1-03
3.00Hz
×
d1-06
V/f voltage value V1
0.0%~100.0%
10.0%
×
d1-07
V/f FREQ value f0
0.00Hz~d1-05
0.00Hz
×
d1-08
V/f voltage value V0
0.0%~100.0%
4.0%
×
d1-09
Torque boost
0.0%~30.0%
0.0%
△
d1-10
Slip compensation gain
0.0%~400.0%
0.0%
△
d1-11
Droop control
0.00Hz~maximum FREQ
0.00Hz
△
d1-12
Current limitation mode
0: Disabled
1: Set by d1-13
2: Set by AI1
3: Set by AI2
4: Set by EAI
5: Set by X6/DI
1
×
d1-13
Digital setting of current
limit value
20.0%~400.0%
150.0%
×
d1-14
Current limit coeff on flux
w eakening
0.001~1.000
0.500
△
d1-15
Energy saving percentage 0%~40.0%
0.0%
△
d1-16
V/f oscillation suppression
gain 1
0~3000
0
△
d1-17
V/f oscillation suppression
gain 2
0~3000
0
△
d1-18
Voltage setting on V/f
separated pattern
0: d1-19 digital setting
1: Set by AI1
2: Set by AI2
3: Set by EAI
4: Process PID output
5: AI1 + process PID output
0
×
d1-19
Digital set voltage on V/f
separated pattern
0.0%~100.0%
0.0%
△
d1-20
Voltage variation time on
V/f separated pattern
0.00s~600.00s
0.01s
△
Group d2 Vector Control Parameters
d2-00
Reserved
Reserved
0
×
d2-01
ASR high-speed
proportional gain Kp1
0.0~20.0
2.0
△
d2-02
ASR high-speed integration 0.000s~8.000s
0.200
△