GK600E User Manual
Chapter 4 Operation and Run Instructions
- 51 -
Exam ple of parameter setting
Exam ple 1
: modify upper limit frequency from 600Hz to 50Hz (change b0-09 from
600.00 to 50.00)
1) In non-parameter edit status, press
to display current parameter A0-00;
2) Press
to move flashing digit to modification bit (A flashes);
3) Press
once to change "A" to "b";
4) Press
to move flashing to modification bit (0 in ones place flashing);
5) Press
nine times to change "0" to "9";
6) Press
to view the parameter value (600.00) of b0-09;
7) Press
to move flashing digit to modification digit (6 flashing);
8) Press
six times to change "6" to "0";
9) Press
once to move flashing digit rightw ards by one bit;
10) Press
for five times to change "0" to "5";
11) Press
to save the value (50.00) of b0-09. Then the control panel w ill
automatically sw itch to display the next function code (b0-10);
12) Press
to exit parameter edit status.
Flow chart is shown below:
Fig. 4-12 Flow chart of upper limit frequency modification
Exam ple 2
: user parameter initialization
1) In non-parameter edit status, press
to display current parameter A0-00;
2) Press
three times to change "0" in the rightmost bit of A0-00 to "3";
3) Press
to display parameter value 0 of A0-03;
4) Press
once to change "0" to "2" or "3" ("2" motor parameter excluded, "3"
means motor parameter included);
5) Press
to save the value of A0-03.Then control panel w ill automatically display
parameter A0-00;
6) Press
to escape parameter edit status.
放弃修改
50.00
ENT
A0-00
A
0-00
>>
b
0-00
▲
>>
b0-0
0
b0-0
9
600.00
6
00.00
0
00.00
0
0
0.00
050.00
b0-09
b0-10
50.00
▲
ENT
>>
▼
>>
▲
ESC
ENT
ESC
Escape modification