Parameter
Designation
Scope
Factory
default
Attr
calibration point 2
C4-04
Input value of AI1
calibration point 2
Range: 0.00V~10.00V
9.00V
×
C4-05
Sampling value of AI2
calibration point 1
Range: -10.00V~10.00V
1.00V
◎
C4-06
Input value of AI2
calibration point 1
Range: -10.00V~10.00V
1.00V
×
C4-07
Sampling value of AI2
calibration point 2
Range: -10.00V~10.00V
9.00V
◎
C4-08
Input value of AI2
calibration point 2
Range: -10.00V~10.00V
9.00V
×
C4-09
Sampling value of EAI
calibration point 1
Range: 0.00V~10.00V
1.00V
◎
C4-10
Input value of EAI
calibration point 1
Range: 0.00V~10.00V
1.00V
×
C4-11
Sampling value of EAI
calibration point 2
Range: 0.00V~10.00V
9.00V
◎
C4-12
Input value of EAI
calibration point 2
Range: 0.00V~10.00V
9.00V
×
Group d Motor and Control Parameters
Group d0 Motor parameters
d0-00
Motor type
0: Ordinary motor
1: Variable frequency motor
1
×
d0-01
Motor pow er rating
0.4kW~6553.5kW
Model
dependent
×
d0-02
Motor rated voltage
0V~480V (for drives 400V level)
380V
×
d0-03
Motor rated current
0.0A~6553.5A
Model
dependent
×
d0-04
Motor rated frequency
0.00Hz~upper limit frequency
50.00Hz
×
d0-05
Motor pole
1~80
4
×
d0-06
Motor rated speed
0~65535r/min
Model
dependent
×
d0-07
Motor stator resistance R1
0.001Ω~65.535Ω
Model
dependent
×
d0-08
Motor leakage inductance
L1
0.1mH~6553.5mH
Model
dependent
×
d0-09
Motor rotor resistance R2
0.001Ω~65.535Ω
Model
dependent
×
d0-10
Motor mutual inductance L2
0.1mH~6553.5mH
Model
×