GK600E User Manual
Chapter 6 List of Parameters
- 105 -
Parameter
Designation
Scope
Factory
default
Attr
FREQ
U0-53
Reserved
Reserved
Reserved
◎
U0-54
Empty car w eight (lift-up)
-300.0%
~
300.0%
0
◎
U0-55
Empty car w eight (lift-dow n)
-300.0%
~
300.0%
0
◎
U0-56
Leveling torque display
-300.0%
~
300.0%
0
Group U1 History Fault
U1-00
History fault 1 (latest)
0: No fault
1: Accel overcurrent
(oC1)
2: Constant-speed overcurrent (oC2)
3: Decel overcurrent (oC3)
4: Accel overvoltage (ov1)
5: Constant-speed overvoltage (ov2)
6: Decel overvoltage (ov3)
7: Module protection (FAL)
8: Autotuning failed (tUN)
9: Drive overloaded (oL1)
10: Motor overloaded (oL2)
11: Current detection abnormal (CtC)
12: Ground short-circuit protection at
output side (GdP)
13: Input pow er supply fault
(ISF)
14: Phase loss at output side (oPL)
15: Inverter module overloaded (oL3)
16: Module overheated (oH1)
17: Motor overheated (PTC) (oH2)
18: Module temperature detection
disconnection (oH3)
19: Reserved
20: Abnormal option board
connection (EC1)
21: Reserved
22: Control board flat cable
connection abnormal (dLC)
23: Analog terminal functional mutex
(TEr)
24: External equipment malfunction
(PEr)
25: Reserved
26: Continuous run time attained (to2)
27: Accumulative run time attained
(to3)
28: Pow er supply abnormal in running
0
◎