GK600E User Manual
Chapter 4 Operation and Run Instructions
- 45 -
4.1.3.5 Parameter Value Setting Status
Enter parameter value setting status upon receipt of pressing
w hen in parameter value
edit status. When pressing
or
command is received in such a state, escape
parameter edit status.
Fig. 4-6 Parameter value setting status (b0-02 is set to 49.83Hz)
4.1.3.6 Password Authentication Status
On condition that parameters are under passw ord protection, users w ould have to go through
passw ord authentication w hen they w ant to modify function code parameter value. Only A0-00
is visible in such a state.
Under passw ord protection, the passw ord authentication status w ill be first entered upon the receipt
of pressing
in STOP parameter display status, run parameter display status, or direct
frequency modification status (refer to the setting method of parameters). It w ill enter parameter edit
status upon the completion of password authentication.
4.1.3.7 Direct Frequency Modification Status
In the status of STOP, fault or run, the drive w ill enter frequency modification status w hen
terminal UP/DOWN is enabled, or pressing
or
.