Chapter 6 List of Parameters GK600E User Manual
- 84 -
Parameter
Designation
Scope
Factory
default
Attr
1: Negative logic
Tens place: X2 (same as ones place)
Hundreds place: X3 (same as ones
place)
Thousands place: X4 (same as ones
place)
C0-15
Digital input terminal
enabled status setting 2
Ones place: X5
0: Positive logic
1: Negative logic
Tens place: X6 (valid as ordinary
terminal, same as ones place)
Hundreds place: (on IO option board,
same as ones place)
Thousands place: reserved
0000
×
C0-16
Digital input terminal
enabled status setting 3
Ones place: AI1
0: Positive logic
1: Negative logic
Tens place: AI2 (same as ones place)
Hundreds place: EAI (on IO option
board, same as ones place)
Thousands place: reserved
0000
×
C0-17
Terminal UP/DOWN FREQ
adjustment action
Ones place: at stop
0: Cleared
1: Maintained
Tens place: on pow er loss
0: Cleared
1: Maintained
Hundreds place: integral function
0: No integral function
1: Integral function enabled
Thousands place: run direction
0: Changing run direction prohibited
1: Changing run direction allow ed
0000
△
C0-18
Terminal UP/DOWN
frequency change step size
0.00Hz/s~100.00Hz/s
0.03 Hz/s
△
C0-19
FWD/REV terminal control
mode
0: Tw o-w ire mode 1
1: Tw o-w ire mode 2
2: Three-w ire mode 1
3: Three-w ire mode 2
0
×
C0-20
Option of virtual input
terminal
000~77F
0: Actual terminal in effect
000
×