A Hilbert Transform will change a radar signal
represented as a time series into its magnitude
(via envelope detection) phase). The Hilbert
Transform expresses the relationship between
the phase and magnitude of the signal, or
between its real and imaginary parts. It allows
the phase of a signal to be reconstructed from
its amplitude.
Toggle Hilbert Transform On or Off by
pressing the Control Knob or the Enter key.
Show Hyperbola:
Toggles a hyperbola On or Off
while in setup or during collection. The hyperbola
appears at the intersection of the vertical and
horizontal cursor. By default the horizontal cursor is
placed at the top of the data display.
•
The hyperbola is used during data collection
to do real-time hyperbola fitting. Hyperbola
fitting measures the geometry of visible
hyperbolas in the data to generate an
estimated Dielectric Constant.
•
During data collection you’ll also have the
option to turn the hyperbola On or Off.
•
Toggle Show Hyperbola On or Off by
pressing the Control Knob or the Enter key.
Colormap:
This menu option offers 30 available Colormap options (i.e. color tables). Select the menu by
pressing the Control Knob or Enter key and then scroll through Colormap #0-29. To preview the different
Colormaps, if the O-Scope is not displayed during data collection, return to the Setup Screen->Output
Menu.
Color Stretch:
Selecting Color Stretch allows you to adjust how the selected Colormap is distributed
over a scan’s amplitude range. A Color Stretch greater than one (1) compresses the colors towards zero
(0). A Color Stretch less than one (1) expands the colors towards the maximum negative and positive
amplitudes. To preview Color Stretch, if the O-Scope is not displayed during data collection, return to the
Setup Screen->Output Menu.
Left Color Stretch = 0; Middle Color Stretch = 1; Right Color Stretch = 3
Color Slide:
Selecting Color Slide allows you to shift the center point of the selected Colormap over a
scan’s amplitude range. A negative number shifts towards the positive amplitudes and positive number
shifts towards the negative amplitudes. To preview Color Slide, if the O-Scope is not displayed during
data collection, return to the Setup Screen->Output Menu.
•
Adjusting the Color Slide over a particular value range allows you to see more subtle variations in
the data.
Summary of Contents for SIR 4000
Page 1: ......
Page 4: ......
Page 116: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 110 ...
Page 140: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 134 ...
Page 150: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 144 ...
Page 156: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 150 ...