Chapter 2 Definition and Connection of Interface Signal
357
Ⅲ
C
o
n
n
e
c
tio
n
pressing
, and is cancelled when the output exceeds the one set by DT13. After the system
executes M32, the lubricating output is executed within the time set by DT13 and it is cancelled.
Execute M33 in the time set by No. 112 and the output is cancelled.
2. Automatic lubricating
When K16.2 is set to 1, the system executes the lubricating in the time set by DT17, and then
stops the output. After it keeps the stop in the time set by DT16, it executes the lubricating again
repetitively, and executes the cycle in turn. In automatic lubricating, M32, M33,
on the
machine panel are valid, and the lubricating time is the one set by DT17.
Note 1: The lubricating output is disabled in emergency stop;
Note 2: K No.0.10 Bit1 sets whether the lubricating output is cancelled in reset:
Bit1
=
0: the lubricating output is disabled in reset;
Bit1
=
1: the lubricating output remains unchanged in reset.
2.8.14 Chuck control
z
Relevant signal (defined by standard PLC program)
DIQP: Chuck control input signal
DOQPJ: Inner chuck clamping output/outer chuck releasing output signal
DOQPS: Inner chuck releasing output/outer chuck clamping output signal
NQPJ: Inner chuck clamping in-position/outer chuck releasing in-position signal, sharing a
common interface with T08, M42I
WQPJ: Inner chuck releasing in-position/outer chuck clamping in-position signal, sharing a
common interface with T07, M41I
Note 1: The key
on the operation panel of GSK980TDc-V can replace DIQP input signal, and the
diagnosis address is X0026.6.
Note 2: NQPJ, WQPJ with the 2
nd
spindle signals SALM2, VPO2 multiplex interface, so, the system does not
check the chuck in-position signal when the multi-spindle function is valid.
z
Signal diagnosis
Signal
DIQP
NQPJ
WQPJ DOQPJ DOQPS
Diagnosis address
X0.2
X3.4
X3.3
Y1.4
Y1.5
Interface pin
CN61.3 CN61.40 CN61.41 CN62.13 CN62.14
z
Control parameter
K 1 2
RCKC CCHU NYQP
SLSP SLQP
SLQP =1: Chuck control function is active;
= 0: Chuck control function is inactive;
SLSP =1: Check chuck clamping when the chuck function is active;
0: Does not check chuck clamping when the chuck function is active; if chuck is not
clamping, the spindle is disabled and an alarm is issued.
Summary of Contents for GSK980TDc
Page 17: ...I Programming ...
Page 18: ...GSK980TDc Turning CNC System User Manual ...
Page 190: ...GSK980TDc Turning CNC System User Manual 172 Ⅰ Programming ...
Page 191: ...Ⅱ Operation Ⅱ Operation ...
Page 192: ...GSK980TDc Turning CNC System User Manua Ⅱ Operation ...
Page 326: ...GSK980TDc Turning CNC System User Manual 306 Ⅱ Operation ...
Page 327: ...Ⅲ Connection Ⅲ Connection ...
Page 328: ...GSK980TDc Turning CNC System User Manual Ⅲ Connection ...
Page 470: ...GSK980TDc Turning CNC System User Manual 448 Ⅲ Connection ...