GSK980TDc Turning CNC System User Manual
308
Ⅲ
Connection
1.1.2 Interface explanation
z
Power box: GSK-PB2, for +5V, +24V, +12V, -12V, GND power supply
z
Filter(optional): Input terminals for 220V AC power, PE terminal for grounding, output
terminals to L, N terminals of GSK-PB2 power box
z
CN1: power supply interface
z
CN11: X axis
,
pin15 D female, connect with X drive unit
z
CN12:
Y
axis
,
pin15 D female, connect with Y drive unit
z
CN13: Z axis
,
pin15 D female, connect with Z drive unit
z
CN14: 4th axis
,
pin15 D female, connect with 4th drive unit
z
CN15: spindle, pin 25 D female, connect with spindle drive unit
z
CN21: encoder, pin15 D male, connect with spindle encoder
z
CN31: MPG, pin26 D male, connect with MPG
z
CN51: communication, pin9 D female, connect PC RS232 interface
z
CN61: input, pin44 D male, connect with machine input
z
CN62: output, pin44 D female, connect with machine output
1.2 GSK980TDc Installation
1.2.1 GSK980TDc external dimensions
See appendix
Ⅰ
,
Ⅱ
.
1.2.2 Preconditions of the cabinet installation
z
The dust, cooling liquid and organic resolution should be effectively prevented from entering the
cabinet;
z
The designed distance between the CNC back cover and the cabinet should be not less than
20cm, the inside and outside temperature difference of the cabinet should be not more than 10
℃
when the cabinet inside temperature rises;
z
Fans can be fixed in the cabinet to ventilate it;
z
The panel should be installed in a place where the cooling can’t splash;
z
The external electrical interference should be taken into consideration in cabinet design to
prevent it from interfering the CNC system.
1.2.3 Measures against interference
In order to insure the CNC stable working, the anti-interference technology such as space
electromagnetic radiation shielding, impact current absorbing, power mixed wave filtering are
employed in CNC design. And the following measures are necessary during CNC connection:
1. Make CNC far from the interference devices (inverter, AC contactor, static generator,
high-voltage generator and powered sectional devices etc.);
2. To supply the CNC via an isolation transformer, the machine with the CNC system should be
grounded, the CNC and drive unit should be connected with independent grounding wires at
the grounding point;
3. To inhibit interference: connect parallel RC circuit at both ends of AC winding (Fig. 1-3a), RC
circuit should approach to inductive loading as close as possible; reversely connect parallel
freewheeling diode at both ends of DC winding (Fig. 1-3b); connect parallel surge absorber at
the ends of AC motor winding (Fig. 1-3c);
Summary of Contents for GSK980TDc
Page 17: ...I Programming ...
Page 18: ...GSK980TDc Turning CNC System User Manual ...
Page 190: ...GSK980TDc Turning CNC System User Manual 172 Ⅰ Programming ...
Page 191: ...Ⅱ Operation Ⅱ Operation ...
Page 192: ...GSK980TDc Turning CNC System User Manua Ⅱ Operation ...
Page 326: ...GSK980TDc Turning CNC System User Manual 306 Ⅱ Operation ...
Page 327: ...Ⅲ Connection Ⅲ Connection ...
Page 328: ...GSK980TDc Turning CNC System User Manual Ⅲ Connection ...
Page 470: ...GSK980TDc Turning CNC System User Manual 448 Ⅲ Connection ...