GSK980TDc Turning CNC System User Manual
310
Ⅲ
Connection
CHAPTER 2 DEFINITION & CONNECTION OF INTERFACE SIGNALS
2.1 Connection to Drive Unit
2.1.1 Drive interface definition
2.1.2 Code pulse and direction signals
nCP+, nCP- are code pulse signals, nDIR+, nDIR- are code direction signals. These two group
signals are both differential output (AM26LS31), it is suggested to receive by AM26LS32 externally,
and the interior circuit for them is shown in Fig. 2-2:
Fig. 2-2 Interior circuit of code pulse and direction signals
2.1.3 Drive unit alarm signal nALM
The low or high level of the drive unit alarm is set by the CNC parameter No.009 Bit0, Bit1, Bit2,
Bit3 and Bit4, its interior circuit is shown in Fig. 2-3:
Fig. 2-3 Interior circuit of drive unit alarm signal
This type of input circuit requires that the drive unit transmits signal by the types in Fig. 2-4:
Signal
Explanation
nCP+, nCP-
Code pulse signal
nDIR+, nDIR-
Code direction signal
nPC Zero
signal
nALM
Drive unit alarm signal
nEN
Axis enable signal
nSET
Pulse disable signal
1: nCP+
2: nDIR+
3: nPC
4: +24V
5: nALM
6: nSET
7: nEN
8:
9: nCP-
10: nDIR-
11: 0V
12: +5V
13: +5V
14: 0V
15: 0V
Fig.2-1
CN11, CN12, CN13, CN14 interface
(15-core D type female socket)
+5V
nALM
+24V
INA Out A
Out A
INB Out B
Out B
nDIR +
nDIR
–
nCP +
nCP–
nDIR
nCP
Summary of Contents for GSK980TDc
Page 17: ...I Programming ...
Page 18: ...GSK980TDc Turning CNC System User Manual ...
Page 190: ...GSK980TDc Turning CNC System User Manual 172 Ⅰ Programming ...
Page 191: ...Ⅱ Operation Ⅱ Operation ...
Page 192: ...GSK980TDc Turning CNC System User Manua Ⅱ Operation ...
Page 326: ...GSK980TDc Turning CNC System User Manual 306 Ⅱ Operation ...
Page 327: ...Ⅲ Connection Ⅲ Connection ...
Page 328: ...GSK980TDc Turning CNC System User Manual Ⅲ Connection ...
Page 470: ...GSK980TDc Turning CNC System User Manual 448 Ⅲ Connection ...