Chapter 2 Definition and Connection of Interface Signal
363
Ⅲ
C
o
n
n
e
c
tio
n
SPB4 =0: When SAGT is at low level (disconnect with +24V), the protection door is closed;
=1: When SAGT is at high level (connected with +24V), the protection door is closed;
SGSP =0: Spindle is disabled when the protection door is open;
=1: Spindle is not disabled when the protection door is open;
z
Function description (defined by standard PLC program)
①
When PB4
=
1, SPB4
=
0, CNC confirms that the safety door is closed as SAGT is connected
to 0V;
②
When PB4
=
1, SPB4
=
1, CNC confirms that the safety door is closed as SAGT is connected
to +24V;
③
In Auto mode, if CNC detects the safety door is open, alarm is issued as cycle starts;
④
In auto running, if CNC detects the safety door is open, the axis feed is held, and alarm is
issued by CNC;
⑤
The safety door detection function is only active in Auto mode;
2.8.19 CNC macro variables
z
Relevant signal
Macro output signal: standard PLC defines 5 macro output interfaces #1100
~
#1105
;
Macro input signal: standard PLC defines 16 macro output interfaces #1000
~
#1015
z
Signal diagnosis
Macro variable number
#1105 #1104
#1103 #1102 #1101 #1100
Diagnosis address
Y3.7 Y3.6 Y3.5
Y3.4 Y3.3
Y3.2
Macro variable number #1007 #1006
#1005 #1004 #1003 #1002 #1001 #1000
Diagnosis address
X0.7
X0.6
X0.5
X0.4 X0.3
X0.2 X0.1 X0.0
Macro variable number #1015 #1014
#1013 #1012 #1011 #1010 #1009 #1008
Diagnosis address
X1.7
X1.6
X1.5
X1.4 X1.3
X1.2 X1.1 X1.0
z
Function description (defined by standard PLC program)
U00
~
U05 signal output may be changed if macro variable
#
1100
~#
1105 are assigned. If
they are assigned for “1”, it outputs 0V, if they are assigned for “0”, it turns off their output signals.
Detect the macro variable
#
1000
~#
1015 values (input signal state), they may be used for
various processing if combined with other transfer judgment macro code.
2.8.20 External override
z
Related signals
Type Symbol
Interface
Address
Function
Remark
Input
signal
OV1
CN61.8
X0.7
External override 1
The external
feedrate override
switch and the tool
signals T5
~
T8
are multiplexed
OV2
CN61.9
X1.0
External override 2
OV3
CN61.10
X1.1
External override 3
OV4
CN61.11
X1.2
External override 4
Summary of Contents for GSK980TDc
Page 17: ...I Programming ...
Page 18: ...GSK980TDc Turning CNC System User Manual ...
Page 190: ...GSK980TDc Turning CNC System User Manual 172 Ⅰ Programming ...
Page 191: ...Ⅱ Operation Ⅱ Operation ...
Page 192: ...GSK980TDc Turning CNC System User Manua Ⅱ Operation ...
Page 326: ...GSK980TDc Turning CNC System User Manual 306 Ⅱ Operation ...
Page 327: ...Ⅲ Connection Ⅲ Connection ...
Page 328: ...GSK980TDc Turning CNC System User Manual Ⅲ Connection ...
Page 470: ...GSK980TDc Turning CNC System User Manual 448 Ⅲ Connection ...