128
Program description: Telemetry menu
SIMPLE DATA VIEW
Select the desired menu line using the arrow buttons
cd
of the left or right-hand touch-key …
TELEMETRY
SETTING & DATA VIEW
SIMPLE DATA VIEW
RF STATUS VIEW
VOICE TRIGGER
… and then briefl y press the central
SET
button of the
right-hand touch-key to bring up a list of further sub-
menus.
SIMPLE DATA VIEW
RECEIVER
RX+ELECTRIC AIRMODUL
RX+GENERAL MODUL
RX+GPS
RX+VARIO MODUL
RECEIVER
RX–S QUA: 100%
RX–S ST : 100%
TX–dBm: 33dBm
RX–dBm: 33dBm
RX–VOLT:4.8 TMP
V–PACK: 10ms
M–RX V :4.6 +22°C
This screen displays the data which can also be viewed
in the “
RX DATAVIEW
” screen of the telemetry menu
“
SETTING & DATA VIEW
”, but in graphic form.
The meanings are as follows:
Value
Explanation
RX-S QUA
Signal quality in %
RX-S ST
Signal strength in %
RX-dBm
Receive performance in dBm
TX-dBm
Transmit power in dBm
V PACK
shows the longest period in ms in
which data packets were lost in
transmission from transmitter to
receiver
RX-VOLT
Current receiver operating voltage in
Volt
M-RX V
Lowest receiver operating voltage in
Volt since the last time it was switched
on
TMP
The thermometer indicates the
receiver’s current operating
temperature
RX + GENERAL MODUL
0.0V
BAT1
BAT2
0.0V T2 +20°C
T1 +20°C
E FUEL F
CELL V
1:0.00
2:0.00
3:0.00
4:0.00
5:0.00
6:0.00
0
0.0V
BAT1
BAT2
0.0V T2 +20°C
T1 +20°C
E FUEL F
ALT
+500m
0m1
0m3
CURRE.
0.0A
POWER
0.0V
If a General Engine module, Order No.
33610
, or a
General Air module, Order No.
33611
, is connected to
the receiver, then this screen provides a graphic display
of the data supplied by it. For more information on these
modules please see the Appendix, or refer to the prod-
uct on the Internet at www.graupner.de.
Depending on the types of sensor fi tted to the modules,
the display constantly shows the following data:
The actual voltage of up to two rechargeable batteries
(BAT1 and BAT2); the measured values from up to two
temperature sensors (T1 and T2) and a fueltank level
indicator.
At the right-hand edge the screen shows either an al-
ternating list of the actual cell voltages of a LiPo battery
with up to six cells, or the current altitude relative to the
location, climb / descent in m/1sec and m/3sec, current
in Ampere plus the actual voltage of the battery con-
nected to the sensor.
SIMPLE DATA VIEW
Summary of Contents for mx-16 HOTT
Page 7: ...7 For your notes...
Page 37: ...37 For your notes...
Page 41: ...41 For your notes...
Page 45: ...45 For your notes...
Page 51: ...51 For your notes...
Page 55: ...55 For your notes...
Page 81: ...81 For your notes...
Page 103: ...103 For your notes...
Page 133: ...133 For your notes...
Page 141: ...141 For your notes...
Page 161: ...161 For your notes...
Page 173: ...173 For your notes...