125
Program description: Telemetry menu
The servo follows the stick movement with a linear
response.
C
: EXPO = +100% and DUAL RATE = 70%
The servo responds slowly to stick movements
around the neutral position, but the curve becomes
steeper with increasing control travel.
Note:
The control characteristics programmed at this point
also affect mapped receiver outputs.
RX SERVO TEST
RX SERVO TEST
ALL–MIN : 1000
μ
sec
ALL–MAX : 2000
μ
sec
ALARM VOLT : 3.8V
TEST : STOP
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
Value
Explanation
Possible settings
ALL-MAX
Servo travel on
the “+” side for all
servo outputs in
the servo test
1500 … 2000 µs
ALL-MIN
Servo travel on
the “-” side for all
servo outputs in
the servo test
1500 … 1000 µs
TEST
Test procedure
START / STOP
ALARM
VOLT
Alarm limit for the
receiver low-
voltage warning
3,0 … 6,0 V
Default setting:
3,8 V
ALARM
TEMP+
Alarm limit for
excessive receiver
temperature
50 … 80 °C
Default setting:
70 °C
ALARM
TEMP–
Alarm limit for
excessively
low receiver
temperature
-20 … +10 °C
Default setting:
-10 °C
CH OUTPUT
TYPE
Channel sequence ONCE, SAME,
SUMI, SUMO
ALL MAX (maximum servo travel)
In this line you can set the maximum servo travel for the
servo test on the plus side of control travel.
2000 µs corresponds to full travel, 1500 µs corresponds
to the neutral position.
ALL MIN (minimum servo travel)
In this line you can set the maximum servo travel for the
servo test on the minus side of control travel.
1000 µs corresponds to full travel, 1500 µs corresponds
to the neutral position.
TEST
In this line you can start and stop the receiver’s integral
servo test.
Touch the central
SET
button of the right-hand touch-key
to activate the input fi eld:
RX SERVO TEST
ALL–MIN : 1000
μ
sec
ALL–MAX : 2000
μ
sec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
TEST :
STOP
Now select
START
with one of the arrow buttons of the
right-hand touch-key:
RX SERVO TEST
ALL–MIN : 1000
μ
sec
ALL–MAX : 2000
μ
sec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
TEST :
START
Touch the central
SET
button of the right-hand touch-
key to start the test-run. The input fi eld now reverts from
highlighted to “normal”:
RX SERVO TEST
ALL–MIN : 1000
μ
sec
ALL–MAX : 2000
μ
sec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
TEST : START
To stop the servo test, re-activate the input fi eld as de-
scribed previously, then select
STOP
and confi rm your
choice with the
SET
button of the right-hand touch-key.
Summary of Contents for mx-16 HOTT
Page 7: ...7 For your notes...
Page 37: ...37 For your notes...
Page 41: ...41 For your notes...
Page 45: ...45 For your notes...
Page 51: ...51 For your notes...
Page 55: ...55 For your notes...
Page 81: ...81 For your notes...
Page 103: ...103 For your notes...
Page 133: ...133 For your notes...
Page 141: ...141 For your notes...
Page 161: ...161 For your notes...
Page 173: ...173 For your notes...