4. Right-click the
Unbound
node for a controller, then select
Bind
in the context menu.
If the RAID chassis has two controllers, both controllers are represented by the single “Controller”
node.
The Bind dialog box opens showing all unbound disks for the controller listed in the Available
Disk list.
5. Leave
Full Bind
unchecked.
6. In the
Bind Type
drop down box, select
RAID 6
.
7. In the Available Disks box, select twelve contiguous disks at the top of the list.
Use ‘shift-click’ or ‘control-click’ to select disks.
8. Click the add (arrow) button to add disks to the Selected Disks list.
NOTE: As an aid in identifying a disk module’s physical location, select it in the Selected
Disks list, then click Identify Disks. This causes the disk drive light to flash.
200
K2 SAN Installation and Service Manual
02 February 2012
Configuring and licensing the K2 SAN
Summary of Contents for K2 BASECAMP EXPRESS
Page 28: ......
Page 38: ......
Page 62: ......
Page 112: ......
Page 124: ......
Page 248: ...248 K2 SAN Installation and Service Manual 02 February 2012 Operating the K2 SAN ...
Page 256: ......
Page 340: ......
Page 354: ......
Page 366: ...366 K2 SAN Installation and Service Manual 02 February 2012 Index ...