2. Expand the tree view to display bound disks.
NOTE: Disks modules may not be visible in the tree view if they are part of a newly bound
RANK. You must restart your RAID chassis and the K2 Media Server to allow the drive modules
to be seen in Storage Utility.
3. Identify the disk in question.
4. Select the disk module icon and check its status, then proceed as follows:
•
If the disk module reports as disabled, proceed to the next step in this procedure.
•
If the disk module reports as online, right-click the disk module and select
Advanced | Disable
Drive
, then click
OK
to continue. A message “…operation succeeded…” appears. The disk is
disabled, as reported by the disk fault LED.
NOTE: If you accidentally disable the wrong disk module, you can enable it again by removing
it and then replacing it in the chassis.
5. Remove and replace the disk module.
Refer to procedures in the Instruction Manual for your RAID storage chassis.
On inserting the replacement disk module, the RAID controller automatically starts rebuilding
the drive. You can verify rebuild status by looking at the disk access LED on the front of the
disk module, or by checking disk status in Storage Utility.
6. Wait approximately 1 minute for the disk to initialize.
The disk ready LED is flashing.
7. To check rebuild status, do the following:
a) Select the replacement disk icon in Storage Utility, then view the disk status in the right-hand
pane. You may need to refresh the Storage Utility display. On completion, the drive status
changes from Rebuilding to Online.
Related Topics
on page 321
Replacing a controller
If the RAID chassis has a single controller (non-redundant), you must take the K2 SAN offline
before replacing a failed controller. Refer to procedures in the Instruction Manual for your RAID
storage chassis. The remainder of this procedure does not apply to non-redundant systems.
If the RAID chassis has redundant controllers and is properly cabled and configured for a redundant
K2 SAN, you can replace a failed controller while media access is underway, as described in this
procedure. When a controller detects a fault on its redundant partner controller, the good controller
disables the faulty controller automatically. In most cases an error message informs you of the fault
and when you check the controller’s status in Storage Utility it reports as disabled.
However, you can also manually disable a controller. In the event that one of the RAID controllers
appears operational, but also reports faults through various log files and status indicators, you can
choose to disable the controller and replace it. Disabling the controller and removing it in this way
avoids interruptions in signal output that can occur if the module fails or if it is simply hot swapped
while it is the active controller. When the replacement RAID controller module is installed, it is
automatically enabled and becomes the backup controller.
330
K2 SAN Installation and Service Manual
02 February 2012
Administering and maintaining the K2 SAN
Summary of Contents for K2 BASECAMP EXPRESS
Page 28: ......
Page 38: ......
Page 62: ......
Page 112: ......
Page 124: ......
Page 248: ...248 K2 SAN Installation and Service Manual 02 February 2012 Operating the K2 SAN ...
Page 256: ......
Page 340: ......
Page 354: ......
Page 366: ...366 K2 SAN Installation and Service Manual 02 February 2012 Index ...